      product thumbnail

      氣體絕緣開關設備
      (Gas Insulated Switchgear)

      In order to guarantee more reliable and stable operation of electric equipment for indoor or outdoor substations, GIS acts as an integrated switchgear that monitors, controls, protects and measures the power systems with protection & control relay panels by safe opening or closing the power lines under the conditions of normal and abnormal operations.

      • Features
      • Specification
      • 下載
      • 客戶支持

      Features

      High Safety

      With metal tank completely earthed and recharging section not exposed outside. not only capacitative induction and contact incident can be avoided, but also fire prevention is accomplishment by using flame retardant SF6 Gas. As controlling lever is not exposed outside, there is no danger to operator's body when controlling.

      Easy Securing Area

      LSIS's GIS takes much less area & space for installation than conventional type because of drastic reduction of required area for its compact size mainly by integrating all the components within the metal SF6 Gas filled-tank which is excellent for di-electric characteristics. It is suitable particularly in a dense areas like city and a place where large space and are not available.

      High Reliability

      Since main parts of switchgear is sealed with SF6 Gas it's free from environmental pollution and climatic change and there's no care about dielectric deterioration by long time operation. The diffusion of accident will be prevented by Gas Section in the case of internal accident. As the operating lever is designed to fit in such manner not to be exposed outside, malfunction caused by freezing and so on can be prevented. The merit when adapting an operating method by oil pressure is that it can be used almost permanently owing to the main components composed together within the oil which lessen the concern for aging and wearing off.

      Easy Installation and Maintenance

      Compact product size makes it possible to shorten the installation period remarkably due to its far more simple installation method than conventional type as well as for easy transportation to site. In addition, Installation without power shut down become possible for expansion works in the future and maintenance works is possible during operation because main components are concealed within SF6 Gas without being influenced by outside factors. Unlike pneumatic generator no regular check (more than 1 time a week) is required-featuring the maintenance free type.

      Specification

        GasInsulatedSwitchgear7-s1.pngGasInsulatedSwitchgear5-s1.pngGasInsulatedSwitchgear8-s1.pngGasInsulatedSwitchgear6-s1.pngGasInsulatedSwitchgear2-s1.pngGasInsulatedSwitchgear1-s1.pngGasInsulatedSwitchgear4-s1.png
        25.8 / 3672.5145170245362420
      Rated VoltagekV, rms25.83672.5145170245362420
      Rated short time current

      kA,rms

      25/40402031.540504050506350
      Rated short timesec33133133113
      Rated breaking current

      kA,rms

      40402031.540504050506350
      Rated currentA,rms~31501250
            /2000
      2000~31501250.2000,
            3150,4000
      Up to 3150Up to 3150  4000       Up to 63004000
      Rated FrequencyHz50/60506050/6050/606050/6050606050
      Rated making current

      kA,peak

      10050/1005079100/104130104130130164125
      Rated breaking timeCycle32
      Power
            Frequency
            Withstand
            Voltage
      CommonkV,rms7070140275325460520650
      Across the
            Insulating
            distance
      kV,rms7780160315375530675815
      Lightning
            Impulse
            Withstand
            Voltage
      CommonkV,peak150170325650750105011751425
      Across the
            Insulating
            distance
      kV,peak165195375750860120011751425(+200)
      Rated operating sequence-O-0.3sec-CO-3min-CO
      Phase
            Arrangement
      Busbar-3Phase
            Encapsulate
      3Phase
            Encapsulate
      2Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      Single Phase
            Segregated
      Feeder-3Phase
            Encapsulate
      3Phase
            Encapsulate
      2Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      Single Phase
            Segregated
      Single Phase
            Segregated
      Single Phase
            Segregated
      Operating
            Mechanism
      CB-Motor Spring

      Motor Spring

      HydraulicMotor SpringMotor SpringMotor SpringHydraulicMotor SpringHydraulicHydraulic
      DS-MotorMotorMotorMotorMotorMotorMotorMotorMotor
      ES-MotorMotorManualMotorMotor SpringMotor Spring,
            Manual
      Motor,
            Manual
      Motor,
            Motor Spring
      Motor,
            Motor Spring
      Motor
      Applicable Standard-IEC62271
            -100,200

      IEC62271
             -200

      IEC 62271-203 / IEC 62271-102 / IEC 62271-100 / IEC 62271-203 / IEC 62271-102 
             

      Features

      High Safety

      With metal tank completely earthed and recharging section not exposed outside. not only capacitative induction and contact incident can be avoided, but also fire prevention is accomplishment by using flame retardant SF6 Gas. As controlling lever is not exposed outside, there is no danger to operator's body when controlling.

      Easy Securing Area

      LSIS's GIS takes much less area & space for installation than conventional type because of drastic reduction of required area for its compact size mainly by integrating all the components within the metal SF6 Gas filled-tank which is excellent for di-electric characteristics. It is suitable particularly in a dense areas like city and a place where large space and are not available.

      High Reliability

      Since main parts of switchgear is sealed with SF6 Gas it's free from environmental pollution and climatic change and there's no care about dielectric deterioration by long time operation. The diffusion of accident will be prevented by Gas Section in the case of internal accident. As the operating lever is designed to fit in such manner not to be exposed outside, malfunction caused by freezing and so on can be prevented. The merit when adapting an operating method by oil pressure is that it can be used almost permanently owing to the main components composed together within the oil which lessen the concern for aging and wearing off.

      Easy Installation and Maintenance

      Compact product size makes it possible to shorten the installation period remarkably due to its far more simple installation method than conventional type as well as for easy transportation to site. In addition, Installation without power shut down become possible for expansion works in the future and maintenance works is possible during operation because main components are concealed within SF6 Gas without being influenced by outside factors. Unlike pneumatic generator no regular check (more than 1 time a week) is required-featuring the maintenance free type.

      Specification

        GasInsulatedSwitchgear7-s1.pngGasInsulatedSwitchgear5-s1.pngGasInsulatedSwitchgear8-s1.pngGasInsulatedSwitchgear6-s1.pngGasInsulatedSwitchgear2-s1.pngGasInsulatedSwitchgear1-s1.pngGasInsulatedSwitchgear4-s1.png
        25.8 / 3672.5145170245362420
      Rated VoltagekV, rms25.83672.5145170245362420
      Rated short time current

      kA,rms

      25/40402031.540504050506350
      Rated short timesec33133133113
      Rated breaking current

      kA,rms

      40402031.540504050506350
      Rated currentA,rms~31501250
            /2000
      2000~31501250.2000,
            3150,4000
      Up to 3150Up to 3150  4000       Up to 63004000
      Rated FrequencyHz50/60506050/6050/606050/6050606050
      Rated making current

      kA,peak

      10050/1005079100/104130104130130164125
      Rated breaking timeCycle32
      Power
            Frequency
            Withstand
            Voltage
      CommonkV,rms7070140275325460520650
      Across the
            Insulating
            distance
      kV,rms7780160315375530675815
      Lightning
            Impulse
            Withstand
            Voltage
      CommonkV,peak150170325650750105011751425
      Across the
            Insulating
            distance
      kV,peak165195375750860120011751425(+200)
      Rated operating sequence-O-0.3sec-CO-3min-CO
      Phase
            Arrangement
      Busbar-3Phase
            Encapsulate
      3Phase
            Encapsulate
      2Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      Single Phase
            Segregated
      Feeder-3Phase
            Encapsulate
      3Phase
            Encapsulate
      2Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      3Phase
            Encapsulate
      Single Phase
            Segregated
      Single Phase
            Segregated
      Single Phase
            Segregated
      Operating
            Mechanism
      CB-Motor Spring

      Motor Spring

      HydraulicMotor SpringMotor SpringMotor SpringHydraulicMotor SpringHydraulicHydraulic
      DS-MotorMotorMotorMotorMotorMotorMotorMotorMotor
      ES-MotorMotorManualMotorMotor SpringMotor Spring,
            Manual
      Motor,
            Manual
      Motor,
            Motor Spring
      Motor,
            Motor Spring
      Motor
      Applicable Standard-IEC62271
            -100,200

      IEC62271
             -200

      IEC 62271-203 / IEC 62271-102 / IEC 62271-100 / IEC 62271-203 / IEC 62271-102 
             

      下載

      主題 分類 語言 修改日期

      客戶支持

      常見問題 more
      聯系我們 more
      top